Defensor PH28A Instructions d'exploitation Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
11
Twosilverionisationelectrodespreventtheformationofslimeandmicroorganismsinthebasetub
andonthehumidicationdrum.TheionizerelectrodesareactiveassoonastheDefensorPH28/
PH28A is switched on.
Operating modes
TheDefensorPH28/PH28Acanbeoperatedinthefollowingoperatingmodes:
Operationasairhumidier
Inthehumidiermodetheventilatorandthehumidicationdrumarerunningonly,iftheactual
humidityvalueisbelowthesetreferencevalue.
Note:iftheactualhumidityvalueremainsbelowthereferencevalueforaprolongedperiodof
time,thefanmustbeswitchedtothenexthighestlevel.
Operation as airpurier(withouthumidication)
Inthisoperatingmodethefanisrunningcontinuously.Thehumidicationdrumremainsswitched
off.
Operation as airpurier/humidier(Combinedmode)
Inthisoperatingmodethefanisrunningcontinuously.Thehumidicationdrumisonlyswitched
oniftheactualhumidityvalueisbelowthesetreferencevalue.
3.6 Options
DefensorPH28 DefensorPH28A
Radio humidity sensor
Theradiohumiditysensorcanbeusedinsteadoftheinte-
gratedhumiditysensor.Themaximumrangeoftheradio
humidity sensor in an open room is 25 m
Note: the radio humidity sensor as well as the receiver
boardmustbeinstalledandconguredonlybyaservice
technicianofyourDefensorrepresentative.